R50x3_single

Small-scale RUO Processing Assemblies

Static electroporation processing assemblies for research applications in small volume scales with both single-well and multi-well options.

Row herosectionWave Shape Decorative svg added to top
Row seperator4 Shape Decorative svg added to bottom

Research Use Only (RUO) Processing assemblies aid the discovery and development of applications at small scales. These static electroporation consumables are made from high-grade, inert materials to protect precious cells with additional design features for easy sample loading and recovery.

Choose the right processing assembly for your application

OC-25x3TM

Small volume for limited cell number applications, multi-well

OC-25x3â„¢

Small volume for limited cell number applications
Multi-well for increased throughput; lower cost per transfection
V-shaped well design for efficient cell recovery

Configuration: 3-well, 25 µL maximum volume per well
Cell Range: 1x105 - 5x106 per well
Volume Range: 20 - 25 µL per well
Application: Research Use Only
Catalog: SOC-25x3

GFP-OC-25x3-v-OC-100@2x

Graph Details: K562 cells were suspended in MaxCyte® Electroporation Buffer with pGFP at low concentration (200 µg/mL) or high concentration concentration (400 µg/mL) and transfected in replicates of 2 processing assemblies using low, medium and high electroporation energy. GFP fluorescence was assessed by flow cytometry 24 hours after electroporation.

atx@2x (1)

For small to medium scale transfection

stx@2x (1)

For high yield transient expression of complex proteins, vaccines and biologics

R-50x3TM

Small volume applications and optimization, multi-well

R-50x3â„¢

Research & development applications
Efficient 3 sample processing per transfection
Easy cell recovery with V-shaped well design

Configuration: 3-well, 55 µL maximum volume per well
Cell Range: 2.25x105 – 1.1x107 per well
Volume Range: 45 - 55 µL per well
Application: Research Use Only
Catalog: ER050U3-10

GFP_Wash-U-Beta-Data@2x

Graph Details: Primary human natural killer (NK) cells were collected from 4 individual donors and activated overnight in 1 ng/mL IL-15. The following day, 3 - 4 x 106 NK cells along with 5 μg mRNA GFP and 45 μL MaxCyte Electroporation Buffer was loaded into each well of the R-50x3 processing assembly and the OC-100 was used as the device control. Cells were electroporated on the MaxCyte GTx™ instrument, then collected and cultured in 1 ng/mL IL-15 media for 24 hours then assessed by flow cytometry. Graphs show the average results and standard error of cells taken from 4 individual donors electroporated with 5 processing assemblies, 2 used for the same donor, with each well of the R-50x3 analyzed individually. The negative control is the average of 4 samples. Experimental data courtesy of Dr. Todd Fehniger’s Laboratory, Washington University in St Louis, Department of Medicine, Division of Oncology with special appreciation to Pamela Wong.

atx@2x (1)

For small to medium scale transfection

stx@2x (1)

For high yield transient expression of complex proteins, vaccines and biologics

R-50x8TM

Small volume discovery applications, multi-well strip

R-50x8â„¢

8-wells for increased throughput; lower cost per transfection
U-shaped well design for efficient cell loading and recovery
Sample tracking with A-H lettering and front writing space

Configuration: 8-well, 55 µL maximum volume per well
Cell Range: 2.25x105– 1.1x107 per well
Volume Range: 45 - 55 µL per well
Application: Research Use Only
Catalog: ER050U8-03

R-50x8-Viability-Data@2x

Graph Details: K562 cells at 5x107 cells/mL were electroporated with plasmid DNA encoding GFP at low energy (Opt-1) and high energy (Opt-10). Four R-50x8 PAs and eight OC-100 PAs were evaluated at each energy level for both GFP expression and cell viability 48 hours post-transfection via flow cytometry analysis. Results are an average of 16 wells for the R-50x8 and 8 wells for the OC-100 for each energy level.

atx@2x (1)

For small to medium scale transfection

stx@2x (1)

For high yield transient expression of complex proteins, vaccines and biologics

OC-100TM RUO

Small volume applications and optimization, single-well

OC-100â„¢ RUO

Small volume applications and experimental optimization
For quick single sample transfection
Well designed for efficient cell loading and recovery

Configuration: Single well, 100 µL maximum volume
Cell Range: 2.5x105 – 2x107
Volume Range: 50 - 100 µL
Application: Research Use Only
Catalog: SOC-1

GFP-OC-25x3-v-OC-100@2x

Graph Details: K562 cells were suspended in MaxCyte Electroporation Buffer with pGFP at low concentration (200 µg/mL) or high concentration concentration (400 µg/mL) and transfected in replicates of 2 processing assemblies using low, medium and high electroporation energy. GFP fluorescence was assessed by flow cytometry 24 hours after electroporation.

atx@2x (1)

For small to medium scale transfection

stx@2x (1)

For high yield transient expression of complex proteins, vaccines and biologics

OC-100x2TM

Small volume applications and optimization, multi-well

OC-100x2â„¢

Multi-well for increased throughput; lower cost per transfection
V-shaped well design for efficient cell recovery

Configuration: 2-well, 100 µL maximum volume per well
Cell Range: 2.5x105 – 2x107 per well
Volume Range: 50 - 100 µL per well
Application: Research Use Only
Catalog: SOC-1x2

OC-400-v-CL-1@2x

Graph Details: K562 cells were suspended in MaxCyte Electroporation Buffer with pGFP into each well of 3 OC-100x2 PAs and 3 OC-100 PAs. Samples were analyzed 24 hours post-electroporation and assayed for fluorescence to measure efficiency. The average for each well is shown in the graph.

atx@2x (1)

For small to medium scale transfection

stx@2x (1)

For high yield transient expression of complex proteins, vaccines and biologics

Row seperator3 Shape Decorative svg added to top

Reagents & Supporting Products

Related products to consider with the small-scale series of Processing Assemblies.

Hyclone-Buffer@2x

Buffer MaxCyte Electroporation Buffer that works with all cell types

PX5

Px5 Workflow Rack Static Processing Assembly rack to assist with workflow management

8_well-rack@2x

Px6s Workflow Rack Strip Processing Assembly rack to assist with workflow management

cock_closed@2x

ExPERTâ„¢ Docking Station Strip Processing Assembly adapter for safe electroporation on all instruments

Find More

Need additional information or assistance choosing the right processing assembly?

about-maxcyte@2x